Skip to content

Choose Update Method

If you try to update a cue in a cue list, the console ask to choose the update method.

Figure 1: Choose Update Method Window

There are two update modes available.

To leave the window, tap Esc in the title bar or press Esc on the console.
The update process is canceled.

For more information about Update, refer to Update command and Update key.

The following tables explains the functions of the two methods on an example.

Cue listFixture 1Fixture 2Fixture 3
Cue 1100 %0 %0 %
Cue 2100 % tracked value50 %0 % tracked value
Cue 3100 % tracked value50 % tracked value25 %
Cue listFixture 1Fixture 2Fixture 3
Cue 1100 %0 %0 %
Cue 2 Update30 %30 %30 %
Cue 330 % tracked value30 % tracked value25 %
Cue listFixture 1Fixture 2Fixture 3
Cue 1100 %0 %0 %
Cue 2 Update30 %30 %30 %
Cue 3100 %50 %25 %